Location -> Electrode pen

Type:Process pH Electrodes
Illustrate:Process pH Electrodes *Adoption of the most advanced Teflon diaphragm with large ring section make the electrode with stable liquid junction.
Process pH Electrodes
*Adoption of the most advanced Teflon diaphragm with large ring section make the
electrode with stable liquid junction.
*Unique structure prevent the electrode from easy pollution and blockage; Long life.
*The reference system is filled with high polymer. Convenient use. Unnecessary to fill electrolyte.
*Installation with ¾"NPT pipe thread with safe and reliable sealing.
*The outer tube material: PPS plastic.
*The electrode has the fixed cable. The length of the cable can be adjusted according to the requirements of the user.

Model CX-PH-0113 pH Combination Electrode
On site routine pH measurement for polluted water.
pH Range: 0-14
Temp.Range(C): 5-80
Sensitive Membrane Shape: Glass Hemisphere
Shaft Length (mm) :165

Model CX-PH-0113 pH Combination Electrode
Adoption of sensitive glass membrane with low impedance
On site routine pH measurement for pure water.
pH Range: 2-12
Temp.Range(C): 5-80
Sensitive Membrane Shape: Glass Hemisphere
Shaft Length (mm) :165
ModeI CX-PH-0114 pH Combination Electrode
Flat surface electrode

On site routine pH measurement for polluted water.
pH Range: 0-14
Temp.Range(C): 5-80
Sensitive Membrane Shape: Flat
Shaft Length (mm): 165
Model CX-ORP-0205 ORP Combination Electrode
On site routine ORP measurement
Measuring Range:+/-1999mV
Temp.Range(C):5-80
Sensitive Membrane Shape: Pt. Band

Shaft Length (mm): 165
Model CX-3T-0501 Triode 3-in-1 pH/ATC Probe
On site routine pH measurement with ATC. Temperature sensor
can be platinum (Pt 100, Pt 1000) or thermistor as required.
pH Range: 0-14
Temp.Range(C): 5-80
Sensitive Membrane Shape: Glass Hemisphere
Shaft Length (mm): 165
*Adoption of the most advanced Teflon diaphragm with large ring section make the
electrode with stable liquid junction.
*Unique structure prevent the electrode from easy pollution and blockage; Long life.
*The reference system is filled with high polymer. Convenient use. Unnecessary to fill electrolyte.
*Installation with ¾"NPT pipe thread with safe and reliable sealing.
*The outer tube material: PPS plastic.
*The electrode has the fixed cable. The length of the cable can be adjusted according to the requirements of the user.

Model CX-PH-0113 pH Combination Electrode
On site routine pH measurement for polluted water.
pH Range: 0-14
Temp.Range(C): 5-80
Sensitive Membrane Shape: Glass Hemisphere
Shaft Length (mm) :165

Model CX-PH-0113 pH Combination Electrode
Adoption of sensitive glass membrane with low impedance
On site routine pH measurement for pure water.
pH Range: 2-12
Temp.Range(C): 5-80
Sensitive Membrane Shape: Glass Hemisphere
Shaft Length (mm) :165
ModeI CX-PH-0114 pH Combination Electrode
Flat surface electrode

On site routine pH measurement for polluted water.
pH Range: 0-14
Temp.Range(C): 5-80
Sensitive Membrane Shape: Flat
Shaft Length (mm): 165
Model CX-ORP-0205 ORP Combination Electrode
On site routine ORP measurement
Measuring Range:+/-1999mV
Temp.Range(C):5-80
Sensitive Membrane Shape: Pt. Band

Shaft Length (mm): 165
Model CX-3T-0501 Triode 3-in-1 pH/ATC Probe
On site routine pH measurement with ATC. Temperature sensor
can be platinum (Pt 100, Pt 1000) or thermistor as required.
pH Range: 0-14
Temp.Range(C): 5-80
Sensitive Membrane Shape: Glass Hemisphere
Shaft Length (mm): 165
Last:Without the Next:Precision pH,ORP Meter