Location -> Products -> Water Treatment -> On-line Instrument -> Industry Chlorine Meter

Type:CX-IAC-1501 industrial acid concentration meter
Illustrate:It’s widely used for continuous monitoring of residual chlorine and PH values of a variety of water quality in electric power plants, water plants, hospitals and other industries
CX-IAC-1501 On-line Residual Chlorine Analyzer
Brief Introduction1.It is a new residual chlorine analyzer manufactured by our company
2.CX-IAC-1501 is a high-intelligence on-line monitor, which is composed of the sensor and the secondary instrument.
3.It can measure residual chlorine, PH and temperature simultaneously.
Main Features
1.Multi-parameter display: On the same screen, residual chlorine, temperature, PH value, output current (HOCL or chlorine electrode input current), status and time are displayed.
2.History curve: It automatically stores residual chlorine measurement data every 5 minutes and it can continuously tore a months of residual chlorine values. On the same screen, it provides “History Curve” display and “Timed” query.
3.Notepad: The notepad faithfully records the operation of the instrument and the occurrence time of the alarm, easy for management.
4.Monitoring electrode: The calibration mode, the time and the result are recorded every time, easy to inquire and analyze the electrode changes.
5.Clock: It provides different time references.
6.Excellent display: It adopts 192×64 bitmap format backlit LCD display, achieving graPHics and Chinese display. With the adjustable uniform background light, you can clearly observe and operate the instrument in the dark conditions outdoors.
7.Stable instrument not crashing: The watchdog process ensures the instrument to work continuously and not to crash.
8.Manual current source function: You can check and arbitrarily set the output current value, facilitating to detect
the recorder and the lower computer.
9.Software set current output mode: Software selection is 0~10mA or 4~ 20mA output, and the user needn’t push
any switch.
Main Parameters
Measuring range |
Residual chlorine: 0-20.00mg/L, Resolution: 0.01mg/L; HOCL: 0-10.00mg/L Resolution: 0.01mg/L; PH value: 0 - 14.00PH Resolution: 0.01PH; Temperature: 0- 99.9 °C Resolution: 0.1 °C |
Accuracy |
Residual chlorine: ± 2% or ± 0.035mg / L, take the bigger; HOCL: ± 2% or ± 0.035mg / L, take the bigger; PH value: ± 0.05PH Temperature: ± 0.5 °C (0 ~ 60.0 °C) |
Sample temperature | 0 ~ 60.0 °C, 0.6MPa |
Sample flow rate | 200 to 250 mL/1min Automatic and Adjustable |
Minimum detection limit | 0.01mg / L |
Repeatability error of the electronic units | Residual chlorine: ± 0.02mg/L, PH value: ± 0.02PH |
Stability | Residual chlorine: ± 0.02 (mg / L)/24h, PH value: ± 0.02PH/24h |
PH Input Impedance | ≥ 1012 Ω |
Clock accuracy | ± 1 min/month |
Isolated current output | 0~10mA(load <1.5 kΩ), 4~20 mA(load <750Ω) |
Output current error | ≤±1%FS |
Data storage capacity | l month (1 point/5 minutes) |
High and low alarm relays | AC220V, 7A; Hysteresis Amount 0- 5.00mg / L; Arbitrary Regulation RS485 communication interface (optional) |
Power Supply | AC220V ± 22V, 50Hz ± 1Hz; DC24V (optional). If it is not specified when ordering, AC220V is the default power supply |
Protection | IP65 |
Power: | ≤ 10W |
Working Conditions: | ambient temperature: 0 ~ 60 °C; relative humidity <85%; |
Overall dimension | 146 (length) x 146 (width) x 108 (depth) mm; dimension of the hole: 138 x 138mm |
Weight | Secondary Instrument: 0.8kg, flow cell with residual chlorine, PH electrode weight: 2.5kg; |
Last:CX-RCA-1503 residual chlorine a.. Next:沒(méi)有了