国产一级a毛一级a看免费视频,久久久久久国产一级AV片,免费一级做a爰片久久毛片潮,国产精品女人精品久久久天天,99久久久无码国产精品免费了

Type:Chlorine Analyzer(polarography)

Illustrate:Electrolyte and permeable membrane separates electrolytic cell and water samples, permeable membrane can be selectively let COL through, there is a fixed potential difference between the sensor and generate electric current intensity can be converted into residual chlorine concentration;

Chlorine Analyzer(polarography)

 ◇Application 
Suitable for drinking water, industrial process hypochlorite disinfection process (HOCL)/
residual chlorine concentration.
◇Characteristic
Wide range and low detection limit
Using selective membrane sensor
With pH and temperature compensation
built-in flow control device
Small amount of maintenance
  ◇Measuring Principle
Electrolyte and permeable membrane separates electrolytic cell and water samples, permeable membrane can be selectively let COL through, there is a fixed potential difference between the sensor and generate electric current intensity can be converted into residual chlorine concentration;
At the cathode: CLO- + 2H+ +2e = CL + H2O
At the anode: CL- + Ag = AgCl + e-
Since in a certain temperature conditions, and p H condition, There exists fixed conversion relationship among HOCL,CLO and residual chlorine. It is use this way to measure the residual chlorine.
◇Parameter
Measuring range:0.05-20.00mg/L HOCL
Minimun detection limit: 0.01mg/L HOCL
Accuracy: 2% or 0.02mg/L HOCL
Response time:90% or less than 90 sec
Sample flow rate:200-1000mL/min
Temperature range:0-45C
Working temperature:0-45C
 
Calibration method: laboratory antitheses
Calibration interval: once/2months
Maintenance interval: normally change the membrane electrolyte(depends on medium)
sample injection connection: dia.10mm hose (inner dia. 6.5mm)
sample excretion connection: dia.10mm hose(inner dia.6.5mm)
box size:350*580*200mm

Parameter
 















Measuring range:0-2ppm, 0-5ppm, 0-10ppm
Measuring accuracy:1% of span
Working temperature:5-45C
Storage temperature:5-50C
Medium flow range:20-90l/h
Water sample pH: 5.5-8.0pH
Water sample conductivity: 50-10000us/cm
Output signal:4-20mA(isolation and non-isolation )
Intersect sensitive: Chloramine, iodine, chlorine dioxide, ozone, bromine and aniline three bromine, etc

  Power supply:24VDC,250mA
 















Instrument Characteristic
◇Large LCD display, see directly
◇High precision, reliable performance
◇Detection residual chlorine, fast response
◇When testing, the flow rate has little influence to it.
◇High and low alarm, safe and reliable
◇4-20 mA signal output, accurate and stable
◇RS485 communication (optional) reliable performance
◇Overall dimensions 145*145*150mm
◇Hole size: 136*136 mm

Parameter
Measuring range:0-20ppm
Measuring accuracy: less than 1% or +/-0.01mg/L. choose larger one
Measure: HOCL/ residual chlorine
Range:0.06-20ppmHOCL or 0.01-5ppm HOCL
Response time:95% 2min (room temperature)
Temperature range:2-45C when working
Minimum flow rate:200-250mL/min, circulate 















type flow can not less than 30L/h
 
 
pH range: 4-8.2pH
Pressure proof range:1bar
Temperature compensation: thermistor, value of resistance customized by user
Electrode cable: 3m high resistance shield cable 
Electrode material: SS316L body material, POM membrane cap, PTFE membrane
Overall dimension: dia:22mm*120mm(length)

 














Parameter
Measuring range:0-2ppm, 0-10ppm
Measuring accuracy:1% of span
Working temperature:5-45C
Storage temperature:5-50C
Medium flow range:20-90L/h 
Water sample pH: 4-11 pH
Water sample conductivity: 50-10000us/cm
Output signal:4-20mA(isolation and non-isolation )
Intersect sensitive: Residual chlorine, ozone and chloramine, etc
Power supply:24VDC,250mA